TFS Takasago Fluidic Systems

Controllers Matrix

April 18, 2024

Controllers used for RP Series (Stepping Motor) and Metered Discharge Pumps

We have a wide selection of controllers and monitors for select tubing pumps. Please refer to the table below and select a controller depending on your pump type and the number of connections. Please feel free to contact us for more information and help choose the correct controller to tailor the operation to your specific needs.


Number Part Number
(Controller)
Type of
Controller
Compatible Pumps Maximum
Pump
Connections
to Main
Controller
Maximum
Connectable
# of
Secondary
Controllers
Maximum
Pump
Connections
per System*1
Pump without Connector Pump with Connector USB Included*2 PC Requirement Remarks
RE-C100 RE-C100 Primary
Controller
RP-HX / TX Series RP-HX: 1
RP-TX: 2
*3
- - Connectable Not
Connectable
- - -
RE-F100 RE-F100 Frequency
Counter
RE-C300 RE-C300 - RP-MC / HC / HⅡC / KⅡC Series 1 - - Not
Connectable
Connectable Included Required Exclusively
for Fixed
Discharge
Pumps
RE-C500 RE-C500 Primary
Controller
RP-HX / TX / QⅡB / QⅢB / QⅡC / QⅢC Series(Series can be mixed) 6
*4
1 12 Not
Connectable
Connectable Included Optional
*5
-
RE-C501 RE-C501 Secondary
Controller
-
RE-C600 RE-C600 - RP-HX / TX / QⅡB / QⅢB / QⅡC / QⅢC Series 1 - - Connectable Connectable Included Optional
*5
Control
the # of
Revolutions
*6
RE-C602 RE-C602 - RP-QⅡF / QⅢF Series 1 - - Connectable Connectable Included Optional
*5
Control
the # of
Revolutions
*6
RE-C700 RE-C700 - RP-H Series 1 - - Connectable Connectable Included Optional*5 Control
the # of
Revolutions
*6

Note: Details such as specifications, etc., may be changed without notice.

*1: Maximum connectable pumps are the total pumps connectable to the main controller and the secondary controller(s).

*2: The USB drive contains software designed for PC, with support for the Windows® 10 operating system.

*3: When RP-TX is connected, the two pumps will operate in the same way.

*4: Pumps can be controlled individually.

*5: A PC is required until the operation sequence program data is saved on the controller.
When changing the operation sequence of the pump, connect it to the PC again to reconfigure the sequence.

*6: The pump can be stopped at a specified number of revolutions (up to 30 revolutions). In addition, fixed volume dispensing at a specified multiples of single dispensing volume per revolution is possible (Single Mode).

*: Controllers and pumps are products of Aquatech Co., Ltd.Aquatech Logo - Small